Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.288
Filtrar
1.
J Long Term Eff Med Implants ; 34(3): 43-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505893

RESUMO

The aim of this systematic review was to identify and analyze the findings of various studies that analyzed the changes in the color stability of maxillofacial prosthetic materials after the addition of various colorants and nanoparticles and assess the change in color after being subjected to either natural or artificial accelerated aging as well as outdoor aging. This systematic review was conducted in accordance with the guidelines of transparent reporting of systematic reviews and meta-analysis (PRISMA Statement). The primary objective of this systematic review was to evaluate the color stability of maxillofacial prosthesis. The secondary objective was to assess the effect of various colorants; pigments; opacifiers; UV absorbers-such as inorganic colorants (dry earth pigments); metal oxides; and organic colorants. The time period of the included studies extended from 2013 to 2023. Electronic database search identified a total of 217 studies. Ten studies were included to meet the research question. All 10 included studies analyzed the effect of various colorants and their exposure to various aging and weathering conditions. It was found that various pigments and nanoparticles had an effect on the color stability. Also weathering and aging conditions had a direct effect on the color stability as well. In terms of disinfection, although there was not much color difference observed, highest change in color stability was observed when rubbing or brushing of the prosthesis was carried out. In conclusion, the color stability of maxillofacial prosthetics is a critical factor that influences both patient satisfaction and the overall cosmetic look. The potential of pigments and nanoparticles to enhance the color stability of silicone-based maxillofacial prosthesis has received much research. By avoiding color fading and discoloration brought on by environmental variables including UV radiation, aging, and chemical exposure, the inclusion of various pigments and nanoparticles has been demonstrated to improve the color stability of silicone maxillofacial prostheses.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Humanos , Elastômeros de Silicone , Cor , Próteses e Implantes , Teste de Materiais
2.
Am J Dent ; 37(1): 9-12, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458976

RESUMO

PURPOSE: To evaluate the influence of group and individual education on shade matching quality using a visual color competency test to match shade tab pairs from two Vita classical A1-D4 shade guides. METHODS: 60 dental students, 21-25 years old (39 females, 21 males) participated in the study. All participants passed a color deficiency test before the experiment. The examination was voluntary and approved by the corresponding Ethics Committee. Students were randomly divided into three groups (n=20): one control group, NE (no education) and two experimental groups - GE (group education) and IE (individual education). The study was performed in three phases. In the "before" (B - Phase 1) and "after" (A - Phase 3) phase, all groups had to match 16 pairs of tabs from two Vita classical A1-D4 shade guides, with the shade designations hidden by custom letter markings. All tabs were mixed on a gray surface illuminated by color-correcting light. In Phase 2 (between B and A), GE had only group education, while IE received additional individual education and training. The control group did not participate in Phase 2. Means and standard deviations were calculated, and differences were compared using the one-way ANOVA, ANCOVA test, and Student t-test for dependent samples (α= 0.05). RESULTS: The NE group matched 10.3 (3.2) and 10.4 (2.9) tab pairs in the before and after phases, respectively. Corresponding results for GE were 11.1 (2.2) and 14.4 (1.9) and 9.5 (3.6) and 15.0 (1.5) for IE, respectively. In Phase 1 (B), no statistically significant difference was recorded among the groups (P= 0.260). The experimental groups achieved a statistically significant improvement compared with the control group in Phase 3 (A) (P< 0.001). Both experimental groups achieved statistically significant improvement within the group after education, GE (P< 0.001) and IE (P< 0.001). Within the limitations of this study, it was concluded that both experimental groups had statistically significant progress in shade matching. The group that received individual education (IE) made statistically significant progress compared with the group that received group education (GE). No statistically significant difference was found in the results of the control group between Phase 1 and Phase 3 of the study. CLINICAL SIGNIFICANCE: Improving the shade matching ability facilitates the work of dentists and dental technicians and enhances the esthetics of dental restorations.


Assuntos
Percepção de Cores , Estudantes de Odontologia , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Cor , Planejamento de Prótese Dentária , Pigmentação em Prótese
3.
J Oral Sci ; 66(2): 116-119, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38447982

RESUMO

PURPOSE: This study investigated the color stability of different commercially available silicone materials for facial prostheses upon exposure to everyday beverages. It was hypothesized that the beverages would not alter the color of the silicone under conditions simulating daily exposure. METHODS: Sixty specimens were fabricated using two materials - VST-50 and Silfy - and exposed to commercially available cold mineral water, tea, or coffee. Specimen color was evaluated on days 1 and 15. The color was measured with a spectrophotometer based on CIELab system and color differences were calculated as ΔE. Statistical analysis was performed using the Kruskal-Wallis test and Mann-Whitney U test. RESULTS: The mean ΔE values after 15 days of exposure to mineral water, cold green tea, and coffee were 1.016, 3.480, and 3.636 for VST-50 and 0.440, 0.798, and 1.425 for Silfy, respectively. Both materials showed significant differences in color, and VST-50 showed a greater color change than Silfy, especially for coffee. CONCLUSION: Pigmented silicone elastomers have low color stability, leading to an overall color change in silicone prostheses when exposed to pigmented beverages. Color changes in such prostheses can be mitigated by selecting materials with better color stability to extend their longevity.


Assuntos
Prótese Maxilofacial , Águas Minerais , Elastômeros de Silicone , Cor , Café , Pigmentação em Prótese , Teste de Materiais , Bebidas
4.
BMC Med Educ ; 24(1): 169, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38389076

RESUMO

BACKGROUND: Selecting the ideal tooth shade is essential to the success of aesthetic dental restorations. Students' cognitive abilities are involved in the multifaceted and intricate process of shade matching. Hence, the present study aimed to assess and compare the shade-matching ability of undergraduate dental students in various years of dental education under clinical and correcting light. METHODS: This comparative cross-sectional study was instigated amongst male 4th, 5th, and 6th-year students of the dental complex of King Faisal University, Kingdom of Saudi Arabia. A total of 72 male dental students assessed the shade under clinical (fluorescent light) and correcting light (handheld Dental Base Light) by using VITA Classical shade guides. Statistical analysis was done using SPSS version 23 (Armonk, NY, USA). The Chi-square test was used to evaluate the association between correct and incorrect shade matching under correcting and clinical light. RESULTS: Out of 72 male students, 22(30.6%) were from the 4th year, 26(36.1%) were from the 5th year, and 24(33.3%) were from the 6th year, with a mean age of 22.92 ± 1.01 years. The majority of the 6th-year students selected shade of anterior tooth # 11 correctly under clinical and correcting light, and 3(12.5%) students selected incorrectly under clinical and correcting light, with a statistically significant association among them (p = 0.004). As far as the shade selection of the posterior tooth is concerned, a statistically significant difference was observed under clinical light among all clinical students (p = 0.008). CONCLUSION: The clinical performance of dental students in shade matching improved with advancing years of dental education. Additionally, the shade matching ability of all groups of dental students was superior under correcting light compared to conditions under clinical light.


Assuntos
Percepção de Cores , Estudantes de Odontologia , Humanos , Masculino , Adulto Jovem , Adulto , Estudos Transversais , Pigmentação em Prótese , Arábia Saudita
5.
J Esthet Restor Dent ; 36(3): 520-526, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38168888

RESUMO

OBJECTIVE: The objective was to assess the repeatability of three spectrophotometers, based on the CIELCh factors and shadeguide reference measurements. MATERIALS AND METHODS: Color analysis was performed using three devices: Rayplicker, Easyshade 4, and Easyshade V. Five repeated measures were performed by the same operator, on the right central maxillary incisor of 30 patients. The CIELCh factors were retrieved and the intra-class correlation was calculated. The Vita Classical and Vita 3D Master shadeguides were used to evaluate the respective Fleiss' Kappa factors. RESULTS: Rayplicker and Easyshade V demonstrated strong intra-class correlation based on the CIELCh factors: 0.98, 0.99, and 0.91 for Rayplicker, and 0.95, 0.99, and 0.93 for Easyshade V, for the L*, C*, and h* parameters, respectively. Regarding the repeatability of the shadeguide data, while Easyshade 4 had the best repeatability when using the Vita Classical as a reference, Rayplicker and Easyshade V showed better repeatability when using the Vita 3D Master. CONCLUSION: These findings suggest that both Rayplicker and Easyshade V are reliable devices for measuring CIELCh parameters. In terms of shadeguide references, the reliability of spectrophotometers is generally lower compared to the CIELCh measurements. CLINICAL SIGNIFICANCE: Given their good repeatability, both the Rayplicker and the Easyshade V spectrophotometers are reliable tools for prosthetic dental practices.


Assuntos
Pigmentação em Prótese , Dente , Humanos , Reprodutibilidade dos Testes , Cor , Espectrofotometria
6.
J Esthet Restor Dent ; 36(1): 116-123, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37086204

RESUMO

OBJECTIVES: To evaluate the influence of the group and individual education of students on shade matching quality. Secondary study objective included a survey-assessment of quality and difficulty level of color matching. MATERIALS AND METHODS: Forty dental student participants in Integrated Academic Studies of Dentistry at the Faculty of Medicine, University of Nis (26 female, 14 male) 21-25 years old, signed consent to voluntarily participate in the research. The Ethics Committee of the Clinic of Dentistry, Faculty of Medicine, University of Nis, approved the study under number 14/11-2019-2EO. They were randomly divided into two groups (n = 20), experimental (IE, individual education) and control (GE, group education). Each group was divided into four subgroups (n = 5). The study was performed in three phases. In Phase I (I) and III (III), students matched the shade of the maxillary central left incisor (#9) using three different shade guides. Each of the students served as a "patient" for shade matching, while the other members of the subgroup, individually (VMI ) and as a team (VMT ), visually matched the tooth shade. In Phase II (between phases I and III), group IE received standard group and individual education and training, while group GE had only group education. Shade matching results in before and after education were compared with results obtained by an intraoral spectrophotometer. CIELAB (∆E*), and CIDE2000 color differences (∆E00 ) were calculated. The color differences between VMI or VMT and ES readings were graded. In addition, the students rated the level of difficulty and quality of shade matching from 1 to 5, signifying the most to least difficult, and the worst to best match, respectively. Means and standard deviations were calculated. Differences were compared using the Student t-test. RESULTS: Means (s.d.) of CIEDE2000 color differences for VMI before and after IE were 4.5 (1.5) and 3.3 (0.9), respectively. Corresponding values for group GE were 4.4 (1.4) and 4.0 (1.0), respectively. As compared with GE, group IE achieved 15% better results for the best matches and 27.5% for one of the three best matches in by-point comparison. Mean (s.d.) results for VMT in the experimental group before and after IE were 3.6 (2.4) and 2.8 (1.6), respectively. Corresponding results for the control group were 4.4 (2.1) and 3.5 (1.7), respectively. Group IE had statistically higher VMI and VMT scores than GE, while, for GE, only VMT scores were statistically higher. Group IE achieved better results in by-point comparison. After education and training, the students rated the shade matching as more precise and less difficult. Results were significantly better for Quality (IE) (sig = 0.010) and Difficulty (GE) (sig = 0.021). CONCLUSIONS: Within the limitations of the study, the experimental group achieved significantly better results in individual color matching after education and training than the control group, while both groups made progress in team color matching. Both groups rated shade matching more accurate and easier after education. CLINICAL SIGNIFICANCE: Improving the quality of shade matching is expected to enhance the esthetics of dental restorations, increase patient satisfaction, and reduce color corrections.


Assuntos
Percepção de Cores , Planejamento de Prótese Dentária , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Cor , Pigmentação em Prótese , Espectrofotometria , Estudantes de Odontologia
7.
J Esthet Restor Dent ; 36(3): 469-476, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37861306

RESUMO

OBJECTIVES: Determine visual 50:50% color difference acceptability thresholds (AT) for regions of the dental color space with varying chromaticity. METHODS: A 40-observer panel belonging to two different groups (dentists and laypersons) evaluated 144 dental resin composites pairs (divided in three different sets of 48 pairs according to chroma value: Low Chroma (LC), Medium Chroma (MC) and High Chroma (HC) placed 40 cm away and inside of a viewing cabinet (D65 Standard light source; diffuse/0° geometry). A Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points and calculate the 50:50% acceptability thresholds in CIEDE2000. A paired t-test was used to evaluate the statistical significance between thresholds differences and Bonferroni correction was applied. RESULTS: The CIEDE2000 50:50% AT were ∆E00 = 2.84, ∆E00 = 2.31 and ∆E00 = 1.80 for LC, MC and HC sets of sample pairs, respectively. The 50:50% AT values were statistically significant between the different sets of sample pairs, as well as the 50:50% AT values obtained for different observer groups. CONCLUSIONS: 50:50% CIEDE2000 acceptability thresholds for dentistry are significantly different depending on the chromaticity of the samples. Observers show higher acceptability for more achromatic samples (low chroma value) than for more chromatic samples. CLINICAL SIGNIFICANCE: The difference in the AT for distinct regions of the dental color space can assist professionals as a quality control tool to assess clinical performance and interpret visual and instrumental findings in clinical dentistry, dental research, and subsequent standardization processes.


Assuntos
Odontologia , Pigmentação em Prótese , Cor , Controle de Qualidade
8.
J Esthet Restor Dent ; 36(3): 421-428, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38053482

RESUMO

STATEMENT OF PROBLEM: The Vita Toothguide 3D-Master (Vita Zahnfabrik) is considered the dental shade guide in which the three dimensions of color - lightness, hue, and chroma - are most well-ordered in the CIELAB color space. No research has yet explored how well the Vita Toothguide 3D-Master is ordered in the 3D color space by recording color coordinates in vivo. PURPOSE: To evaluate the spatial color distribution of the Vita Toothguide 3D-Master's lightness, chroma, and hue groups and its 26 physical shade tabs. MATERIALS AND METHODS: The dental color (L*, C*, h°, a*, and b* color coordinates) of a healthy maxillary central incisor was recorded for 1361 participants (aged between 18 and 89 years) using a Vita Easyshade Compact spectrophotometer (Vita Zahnfabrik). The R 2.7.2. statistics program was used to create the visual representations. RESULTS: The five lightness levels are those that are best distributed in the color space, in relation to the L* coordinates, followed by the chroma group and, finally, the hue group. The 5M1, 5M2, and 5M3 physical shade tabs are situated at a greater distance apart from the other tabs in the color space. CONCLUSIONS: The Vita Toothguide 3D-Master's 26 physical shade tabs are satisfactorily distributed in three-dimensional space, although strict mathematical criteria are not followed. The natural dental shades that fall lower on the lightness scale are the most poorly represented by the physical shade tabs. CLINICAL IMPLICATIONS: Darker teeth are poorly represented by the Vita Toothguide 3D-Master's physical shade tabs. The spatial distribution of dental shade guides needs to be improved to ensure they provide homogeneous coverage of the entire chromatic spectrum corresponding to natural teeth. This would help reduce the errors inherent to the subjective visual color selection process.


Assuntos
Planejamento de Prótese Dentária , Pigmentação em Prótese , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Cor , Pigmentação em Prótese/métodos , Incisivo , Espectrofotometria
9.
Int J Prosthodont ; 36(5): 649, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37921676

RESUMO

PURPOSE: To compare the CIE L*a*b* values of two different dental shade guides using two shade-matching spectrophotometers. MATERIALS AND METHODS: SpectroShade Micro (SS) and Easyshade (ES) (VITA Zahnfabrik) were tested. One calibrated operator performed 30 measurements of each tab from three batches of the two guides, VITA Classical (VC) and VITA 3D Shade Master (VM). Receiver operating characteristic (ROC) curves and intraclass coefficients (ICC) between the different batches were calculated. Results were given as mean and SD of the L*a*b* values and the respective color differences according to the CIEDE 2000 formula (ΔE00) for each of the shade tabs in the two spectrophotometers and then analyzed with independent student t test (α = .05). RESULTS: A total of 1,440 and 2,610 measurements for VC and VM, respectively, were performed per spectrophotometer. There were statistically significant differences between the two devices for all L*a*b* values, with the exception of: L* for 3R1.5; a* for 2R1.5, 3L1.5, 2L2.5, 3M2, 3L2.5, 4L1.5, and 4L2.5; and b* for D3, 1M2, and 3M2. When assessing the same shade guide, differences in ΔE00 were detected between devices above the acceptability threshold (AT) (ΔE00 ≥ 1.8) for all shade tabs except for VC (C1, C2, D3, A3.5, C3, and A4) and VM (4M1, 3R2.5, 4L2.5, and 4M3). The overall mean of the interdevice ΔE00 was 2.2 ± 1.0 for VC and 2.5 ± 1.0 for VM. CONCLUSIONS: The two dental spectrophotometers presented high ICC and ROC values, which validates their indication as auxiliary tools. However, there are discrepancies in the hues D (VC) and R (VM) with interdevice variability when evaluated for the L*a*b* component. Int J Prosthodont 2023;36:e38-e52.


Assuntos
Planejamento de Prótese Dentária , Pigmentação em Prótese , Cor , Espectrofotometria , Colorimetria
10.
Sci Prog ; 106(4): 368504231205392, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37814535

RESUMO

The limited service life of craniofacial prostheses due to degradation and color instability is a significant challenge. This in vitro study aimed to determine how zirconium dioxide (ZrO2) nanoparticles affect the color stability of M511 heat temperature vulcanizing (HTV) maxillofacial silicone elastomers after artificial aging. ZrO2 nanoparticles were added at concentrations of 1, 2, and 3 wt% to M511 HTV silicone elastomer. Two intrinsic silicone pigments were used (red and mocha). Silicone with pigment and without ZrO2 nanoparticles were used as the control. Eighty disk-shaped specimens were fabricated and divided into eight experimental groups, each containing ten specimens (n = 10). All specimens were subjected to artificial aging, and color changes were recorded at 252, 504, and 1008 h intervals. The L*a *b * values were measured using a colorimeter and the CIE-Lab system. To interpret the recorded color differences, a 50:50 percent perceptibility threshold (ΔE* = 1.1) and acceptability threshold (ΔE* = 3.0) were implemented. A one-way analysis of variance and Tukey's post hoc test at a significance level of 0.05 were used for the statistical analysis. We found that every evaluated specimen group exhibited a chromatic change (ΔE* > 0). The ΔE* values for the mocha pigments with and without ZrO2 nanoparticles were below the perceptible threshold (1.1 units). The ΔE* values of the red pigment with and without ZrO2 nanoparticles were significantly higher than the acceptable threshold (P < 0.000). According to the findings of this in vitro study, all the specimens underwent color changes (ΔE* > 0). The red pigment exhibited highly significant chromatic alterations. In contrast, mocha pigments with and without ZrO2 nanoparticles exhibited the least color change and were below the perceptible threshold. ZrO2 nanoparticles provided important protection and showed a reduction in color change.


Assuntos
Temperatura Alta , Elastômeros de Silicone , Cor , Teste de Materiais , Pigmentação em Prótese
11.
J Dent ; 138: 104648, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37536431

RESUMO

OBJECTIVE: (1) To put forward a set of valid pink ceramic samples for subjective gingival colour selection in the Caucasian population, and (2) to assess the quality of the shade matches provided by the selected pink samples. METHODS: The ceramic gingival shade samples (n = 133) were obtained by mixing pairs of basic colours from a single system. In each mixture, the proportions of the colours were altered in 10% increments, following the numerical order used by the manufacturers of the three colour systems under study (Heraceram, Vita VM9 and IPS Style). The CIELAB colour coordinates were recorded using spectrophotometry in three zones of healthy anterior gingiva (n = 360). The sample was randomly divided into two subsamples, each of which contained 180 participants. Subsample 1 was used to select the ceramic gingival samples that provided the best shade matches, using the k-means clustering method. Subsample 2 was used to assess the chromatic validity of the selected gingival samples, according to the coverage error. RESULTS: To identify the ceramic gingival samples that best represented participants' gingival colour, the minimum colour differences (ΔEab∗, ΔE00) between the cluster centroids and the 133 gingival samples were calculated. Fifteen gingival samples were selected: 8 from the Heraceram system, 4 from the VM9 system, and 3 from the IPS Style system. Coverage errors for the 15 gingival samples fell below the gingival clinical acceptability thresholds in the three gingival zones examined. CONCLUSIONS: The 15 ceramic gingival colour samples provide satisfactory coverage of the gingival colour space, with coverage errors below the ΔE00 clinical acceptability threshold of 2.9 units. These pink colour samples have the potential to provide good gingival shade matches in subjective colour selection. CLINICAL SIGNIFICANCE: Mixing basic ceramic colours is a viable method for generating a series of pink shades that can be used as a physical gingival shade guide. The resulting guide provides valid results (under the acceptability thresholds) for subjective selection gingival colour selection in clinical practice.


Assuntos
Colorimetria , Gengiva , Humanos , Cerâmica , Cor , Colorimetria/métodos , Pigmentação em Prótese
12.
J Esthet Restor Dent ; 35(5): 787-795, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37428006

RESUMO

OBJECTIVE: This article introduced a systematic approach to matching composite and tooth shades to create esthetic restorations that visually integrate seamlessly with the patient's tooth and surrounding dentition. A basic explanation of color science was presented to aid the clinician in adopting this systematic approach to color matching. To demonstrate the need for custom shade guides, an objective analysis of composites from different companies was performed by recording the color coordinate values of multiple composites and then calculating CIEDE2000 color differences. Different locations on the tooth were analyzed using the same identified shade from different companies, as well as using the same composite shade applied in different thicknesses. A case report documented the clinical application of these shade matching techniques. CLINICAL CONSIDERATIONS: Shade matching, particularly in the anterior esthetic region, can be challenging, which can result in patient dissatisfaction with the esthetic result. Stock shade tabs are not a reliable indicator of actual composite shades. CONCLUSIONS: The most predictable esthetic results were achieved by using custom shade guides as an entry point, followed by a direct composite color mockup intraorally. CLINICAL SIGNIFICANCE: To consistently meet the esthetic demands of today's patients, dentists need reliable tools when selecting a composite shade for restorations. Composites with the same shade designation vary in color and shade designation cannot be relied upon for accurate shade selection. The use of custom shade guides and an intra-oral mockup can enhance the esthetic outcome.


Assuntos
Planejamento de Prótese Dentária , Pigmentação em Prótese , Humanos , Cor
13.
Syst Rev ; 12(1): 95, 2023 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-37291652

RESUMO

BACKGROUND: Shade determination is a critical step for the fabrication of a satisfactory restoration. Visual shade selection with conventional shade guides is subjective and influenced by variables related to light, observer, and object. Shade selection devices have been introduced to provide subjective and quantitative shade values. This systematic review and meta-analysis aimed to compare the color difference for shade selection with visual and instrumental methods. METHODS: An initial search was conducted on databases (MEDLINE via PubMed, Scopus, and Web of Science) in addition to a manual search through references of identified articles. Studies comparing the accuracy of visual and instrumental shade selection based on ΔΕ were included in data synthesis. Mean differences (MDs) and 95% confidence intervals (CIs) were calculated to estimate the effect size for global and subgroup meta-analysis using the inverse variance weighted method and random-effects model (P ˂ 0.05). Results were presented as forest plots. RESULTS: The authors identified 1776 articles from the initial search. Seven in vivo studies were included in the qualitative analysis of which six studies were included in the meta-analysis. For the global meta-analysis, the pooled mean (95% CI) was - 1.10 (- 1.92, - 0.27). Test for overall effect showed that instrumental methods were significantly more accurate than visual methods with significantly less ΔΕ (P = 0.009). Test for subgroup difference showed that the type of instrumental shade selection method used had a significant effect on accuracy (P ˂ 0.001). Instrumental methods including spectrophotometer, digital camera, and smartphone showed significantly better accuracy compared with visual shade selection (P ˂ 0.05). The greatest mean difference was found between the smartphone and visual method with a mean (95% CI) of - 2.98 (- 3.37, - 2.59) with P ˂ 0.001 followed by digital camera and spectrophotometer. There was no significant difference in accuracy between IOS and visual shade selection (P = 1.00). CONCLUSIONS: Instrumental shade selection with a spectrophotometer, digital camera, and smartphone showed significantly better shade matching compared with a conventional shade guide, whereas IOS did not improve the shade matching significantly compared with shade guides. REVIEW REGISTRATION: PROSPERO CRD42022356545.


Assuntos
Percepção de Cores , Pigmentação em Prótese , Humanos , Cor , Espectrofotometria , Projetos de Pesquisa
14.
J Esthet Restor Dent ; 35(6): 878-885, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37073977

RESUMO

OBJECTIVE: To investigate the effect of cross-polarization filters on the colors of shade tabs obtained with a digital single-lens reflex (DSLR) camera, macrolens, and a ring flash. MATERIALS AND METHODS: Digital images of four shade tables (1M1, 3L2.5, 3R2.5, and 5M3) from the VITA Toothguide 3D-Master shade guide were taken using a DSLR camera, 100 mm macrolens, and ring flash with two different cross-polarizing filters (Polar_eyes and Filtropolar), and without (Nonpolarizer; n = 7). The CIE L*a*b* color coordinates of digital images were calculated and remeasured with a spectroradiometer (SR). The color differences (ΔE00 ) between the SR and digital images were calculated and analyzed with the two-way analysis of variance (ANOVA) and Tukey HSD test (α = 0.05). RESULTS: ΔE00 values of all test groups were higher than the clinically acceptable threshold (∆E00 > 1.80). While the ∆E00 values of Filtropolar (6.19 ± 0.44) and Polar_eyes (7.82 ± 0.23) groups were significantly higher than the Nonpolarizer (4.69 ± 0.32) for the 1M1 shade tab, ∆E00 value of Polar_eyes (6.23 ± 0.34) was significantly lower than Nonpolarizer (10.71 ± 0.48) group for 5M3 shade tab (p < 0.05). CONCLUSION: The color-matching results of tested digital photography techniques with and without cross-polarization were unacceptable, compared to a spectroradiometer. While digital photography with Polar_eyes cross-polarizing filter has closer results to the reference device for the low-in-value shade table (5M3), for the high-in-value shade table (1M1), improved results were obtained without a cross-polarizing filter. CLINICAL SIGNIFICANCE: The cross-polarization filters are increasingly used in dentistry for tooth color communication with digital photography techniques. However, the digital photography techniques with-without cross-polarization filterers should be improved to obtain clinically acceptable color-matching results.


Assuntos
Fotografação , Pigmentação em Prótese , Cor , Fotografação/métodos , Reflexo , Planejamento de Prótese Dentária
15.
Technol Health Care ; 31(5): 1659-1669, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36970918

RESUMO

BACKGROUND: Dentists must be able to identify subtle color changes as shade-matching is crucial in aesthetic dentistry. OBJECTIVE: To determine whether color discrimination ability is related to shade-matching accuracy among dentists. METHODS: The sensitivity of the normal-color vision population to different colors was investigated using Farnsworth Munsell 100 Hue (FM-100) test results. The FM-100 test was administered to 37 dentists at the Hospital of Stomatology, Jilin University. Sensitivity of dentists with normal-color vision to different colors was investigated using the FM-100 test. Participants were instructed to arrange color caps of various colors according to the gradual change in colors and the results were scored. Visual shade matching test using Vita 3D-MASTER shade guide was performed to determine shade-matching accuracy. The relationship between color discrimination ability and shade-matching accuracy was analyzed. The number of misplaced color caps in the FM-100 test was also calculated. RESULTS: The FM-100 test revealed that 16 and 21 participants had excellent and average color discrimination ability, respectively, and their shade-matching accuracies were 68.75% and 66.67%, respectively. No significant difference was observed in the shade-matching accuracy between the two groups. No significant correlation was observed between the color discrimination ability and shade-matching accuracy. In addition, the number of wrong color caps on the 43-63 color tray with the transition from blue-green to blue-purple was the highest according to Friedman's test. CONCLUSION: Color discrimination ability of dentists does not affect their visual shade-matching accuracy. Additionally, people with normal color vision are not sensitive to the transition from blue-green to blue-purple.


Assuntos
Visão de Cores , Humanos , Cor , Odontólogos , Pigmentação em Prótese
16.
Clin Exp Dent Res ; 9(2): 368-374, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36780185

RESUMO

OBJECTIVE: In dental restorations, color determination is very important for achieving esthetic results. The aim of this study was to compare visual shade selection using digital methods and to assess the repeatability of the utilized intraoral scanners. MATERIALS AND METHODS: In 31 probands, tooth color was determined on teeth 11, 13, and 16. Shade selection was performed visually by a dentist and digitally using Trios 3 and Cerec Omnicam. Three measurements were performed to determine the repeatability of intraoral scanners. Fleiss' κ was used for statistical evaluation of the repeatability and Cohen's κ was used for comparison of methods. RESULTS: The visual method showed only slight agreement with Trios 3 (Cohen's κ: 0.198) and Cerec Omnicam (Cohen's κ: 0.115). Moderate agreement was found between Trios 3 and Cerec Omnicam (Cohen's κ: 0.452). In terms of repeatability, Trios 3 scored higher overall than Cerec Omnicam (Fleiss' κ: 0.612 vs. 0.474). CONCLUSION: Intraoral scanners can facilitate the workflow in clinical practice. They are a good supplement for color determination, but should additionally be confirmed by the visual method. Clinical significance: The use of digital instruments is increasingly being preferred over conventional treatments. Therefore, it is essential to continuously improve the accuracy of intraoral scanners for color selection in order to offer an alternative to visual methods.


Assuntos
Dente Canino , Pigmentação em Prótese , Suplementos Nutricionais
17.
J Indian Prosthodont Soc ; 23(1): 84-89, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36588380

RESUMO

Aim: This study aimed to compare the performance of two deep learning algorithms, attention-based gated recurrent unit (GRU), and the artificial neural networks (ANNs) algorithm for coloring silicone maxillofacial prostheses. Settings and Design: This was an in vitro study. Materials and Methods: A total of 21 silicone samples in different colors were produced with four pigments (white, yellow, red, and blue). The color of the samples was measured with a spectrophotometer, then the LFNx01, aFNx01, and bFNx01 values were recorded. The relationship between the LFNx01, aFNx01, and bFNx01 values of each sample and the amount of each pigment in the compound of the same sample was used as the training dataset, entered into each algorithm, and the prediction models were obtained. While generating the prediction model for each sample, the data of the corresponding sample assigned as the target color were excluded. LFNx01, aFNx01, and bFNx01 values of each target sample were entered into the obtained models separately, and recipes indicating the ratios for mixing the four pigments were predicted. The mean absolute error (MAE) and root mean square error (RMSE) values between the original recipe used in the production of each silicone and the recipe created by both prediction models for the same silicone were calculated. Statistical Analysis Used: Data were analyzed with the Student t-test (α=0.05). Results: The mean RMSE values and MAE values for the ANN algorithm (0.029 ± 0.0152 and 0.045 ± 0.0235, respectively) were found significantly higher than the attention-based GRU model (0.001 ± 0.0005 and 0.002 ± 0.0008, respectively) (P < 0.001). Conclusions: Attention-based GRU model provided better performance than the ANN algorithm with respect to the MAE and RMSE values.


Assuntos
Aprendizado Profundo , Prótese Maxilofacial , Humanos , Teste de Materiais , Elastômeros de Silicone , Pigmentação em Prótese , Cor
18.
J Prosthodont ; 32(3): 196-203, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35919949

RESUMO

PURPOSE: The variation in findings with regards to the accuracy and precision of intraoral scanners for shade selection are no doubt confusing for clinicians who may find it difficult to make evidence-based decisions. The aim of this systematic review is to provide a comprehensive and in-depth assessment of available studies to determine the viability of using intraoral scanners for the purpose of shade matching. The PICO-guided research question is as follows: when shade matching, are intraoral scanners as valid as visual or other digital shade measuring devices in determining tooth colors. METHODS: Electronic databases including PubMed/MEDLINE, SCOPUS, EBSCO, Cochrane, and ProQuest were systematically searched for articles published between January 1, 2011 and December 30, 2021 using the main search terms: "intraoral scanners," "scanners," "TRIOS," "CEREC," "Planmeca," "Medit," "digital dentistry" in concurrence with one of the following keywords: "EasyShade" OR "shade selection" OR "shade matching" OR "shade" OR "tooth color" OR "tooth shade" OR "digital shade matching." Bibliographies of included articles and the following journals were searched for relevant articles: Journal of Prosthetic Dentistry, Journal of Prosthodontics, Journal of Esthetic and Restorative Dentistry, Journal of Advanced Prosthodontics, and Journal of Dentistry. A total of 15 articles were included in the review. RESULTS: Intraoral scanners are highly repeatable for shade matching, and outperformed visual shade matching. Accuracy varied significantly between studies, with the majority recommending the use of visual shade matching to confirm/verify the intraoral scanner results. Setting intraoral scanners to the Vita 3D Master shade guide improved both accuracy and precision. Shade matching with intraoral scanners may be influenced by external factors such as ambient light sources and incorrect use or manipulation. CONCLUSION: Intraoral scanners set to the Vita 3D Master shade guide may be used for shade matching, but shade should be verified with visual shade matching. Further studies are required to address limitations of current studies.


Assuntos
Estética Dentária , Dente , Cor , Espectrofotometria/métodos , Pigmentação em Prótese/métodos
19.
Int J Prosthodont ; 36(3): 331­337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35234751

RESUMO

PURPOSE: To determine and compare the accuracy and reliability of shade matching using the conventional and smartphone virtual methods. MATERIALS AND METHODS: A phantom head with both maxillary central incisors removed was set up. A central incisor of various standard shades was inserted into the phantom head. Five undergraduate and five postgraduate students were asked to select the closest shade to match the central incisor using the Vita Classic shade guide. The procedure was then repeated using images taken by a smartphone. Each technique was repeated three times. Differences in accuracy of shade matching between the two techniques for every shade tab and between undergraduate and postgraduate dental students were compared using chi-square statistical analysis. The P value was set at .001. Differences in intra-rater and inter-rater reliability between the two techniques and among the three sessions were compared using paired t test and analysis of variance (ANOVA), respectively, with a P value of .05. The reliability of both techniques was further measured using Cohen kappa statistical test. RESULTS: The smartphone virtual shade-matching technique showed significantly higher accuracy in shade matching with most of the tested shade tabs than the conventional method (P < .001), irrespective of observers' clinical experience. Higher repeatability was found in the virtual technique than the conventional technique, with higher intra-rater and inter-rater reliability observed. CONCLUSION: Smartphone virtual shade matching showed better accuracy and reliability than the conventional method and could be used as an alternative shade-matching method.


Assuntos
Pigmentação em Prótese , Smartphone , Humanos , Espectrofotometria , Cor , Reprodutibilidade dos Testes , Planejamento de Prótese Dentária , Incisivo , Percepção de Cores
20.
J Prosthet Dent ; 129(5): 805-810, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-34649721

RESUMO

STATEMENT OF PROBLEM: Resistance to long-term color change is a desirable property for facial prosthetic elastomers. Evidence for the color stability of maxillofacial silicones under aging and hot and humid Indian weathering conditions is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of adding opacifiers on the color stability of maxillofacial silicone under human aging and Indian weather conditions. MATERIAL AND METHODS: A total of 93 specimen disks were obtained from the A-2186, platinum-based, room-temperature vulcanized, maxillofacial silicone elastomer by using a Ø30×6-mm stainless-steel die. The specimens were divided into 3 main groups (n=30), C (control), T (titanium dioxide), and B (barium sulfate), and 1 additional specimen (n=1) from each group was stored in a closed box and further subgrouped as outdoor weathering (COut, TOut, BOut), acidic perspiration (CAcid, TAcid, BAcid), sebum (CSebum, TSebum, BSebum) (n=10), and visual comparison (CVis, TVis, BVis) (n=1). Baseline L∗, a∗, b∗ values were recorded by using a spectrophotometer and visual perception. The specimens were subjected to human and extraoral aging conditions, and the values were recorded again after 6 months. Data were analyzed statistically by using analysis of variance (ANOVA) and post hoc analysis with the Tukey post hoc test. RESULTS: In group C, the mean color change for COut was 3.69 ±0.49; CAcid, 3.58 ±0.68; and CSebum, 7.53 ±0.22 (P<.001). In group T, the mean color change for TOut was 2.60 ±0.24; TAcid, 2.35 ±0.13; and TSebum, 4.91 ±0.44 (P<.001). In group B, BOut was 1.59 ±0.28, BAcid was 1.46 ±0.28, and BSebum was 4.03 ±0.71 (P<.001). The specimens containing barium sulfate showed the maximum color stability. The least color stability was observed in all specimens exposed to sebum solution and was significantly different (P<.001) from the outdoor weather and acidic perspiration specimens. Visually perceivable color changes were observed in specimens exposed to the sebum solution. CONCLUSIONS: The addition of titanium dioxide and barium sulfate as opacifiers resulted in clinically acceptable color change when exposed to outdoor weathering and acidic perspiration but not in sebum solution.


Assuntos
Sulfato de Bário , Prótese Maxilofacial , Humanos , Teste de Materiais , Cor , Pigmentação em Prótese , Tempo (Meteorologia) , Elastômeros de Silicone
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...